B-63783EN-1/01 9.SPINDLE FUNCTION
- 959 -
5711 Maximum spindle speed during rigid tapping (first stage)
5712 Maximum spindle speed during rigid tapping (second stage)
5713 Maximum spindle speed during rigid tapping (third stage)
5714 Maximum spindle speed during rigid tapping (fourth stage)
5715 Maximum spindle speed during rigid tapping (fifth stage)
5716 Maximum spindle speed during rigid tapping (sixth stage)
5717 Maximum spindle speed during rigid tapping (seventh stage)
5718 Maximum spindle speed during rigid tapping (eighth stage)
[Input type] Parameter input
[Data type] Integerspindle
[Unit of data] min
-1
[Valid data range] 0 - 999999999
These parameters specify the maximum spindle speed used for each
gear stage during rigid tapping. Issuing an S command having a
value larger than each specified value is results in an alarm.
NOTE
No check is made if all of values specified in
parameter Nos. 5711 to 5718 are 0.
If a nonzero value is specified in a parameter for
the "ath" gear stage, and all the parameters for
gears lower than the "ath" gear stage are reset
to 0, a check is made with a value specified for
the "ath" gear stage if the "ath" stage or a lower
stage is selected.
For example, when parameter Nos. 5711 to
5713 = 0, parameter No. 5714 = 800, and
parameter Nos. 5715 to 5718 = 0, a check is
made with an upper limit of S800 if the fourth
stage or a lower stage is selected.
Alarm and message
Number Message Description
PS0544 S-CODE OVER MAX The S command has exceeded the maximum spindle
rotation speed.