B-63783EN-1/01 12.DISPLAY/SET/EDIT
- 1339 -
Signals
Torque sensing command signal
FTCMD<G149#0>
[Classification] Input signal
[Function] This signal directs that disturbance load torque data be stored.
[Operation] While the torque sensing command signal is "1", the CNC stores
disturbance torque data to memory. When the signal changes from "1"
to "0", the CNC stops storing the torque data. When the signal changes
back to "1", the CNC restarts to store the torque data. When new torque
data is to be stored, the store counter clear signal must be input.
Store counter clear signal
FTCLR<G149#2>
[Classification] Input signal
[Function] This signal clears the counter for the stored data.
[Operation] When the store counter clear signal becomes "1", the CNC deletes all
stored data, and clears the counter for the stored data. Newly starting to
store data requires that the store counter clear signal be input.
Signal addresses
#7 #6 #5 #4 #3 #2 #1 #0
G149 FTCLR FTCMD
Alarm and message
Number Message Description
SR1055 ILLEGAL FINE TORQUE SENSING
PARAMETER
The setting of a fine torque sensing parameter is invalid.
An invalid controlled-axis number was specified for a target
axis.
Store counter
(the quantity of stored data items)
Time
FTCMD
FTCLR