9.SPINDLE FUNCTION B-63783EN-1/01
- 788 -
Note 1)
The data list at the CNC side corresponds to that at the spindle side, as
follows:
CNC parameter numbers : Cn, Cn+1
Spindle parameter number : Sm
Sm Cn Cn
+1
Note 2)
The data list at the CNS side corresponds to that at the spindle side, as
follows:
CNC parameter number : Cm
Spindle parameter numbers : Sn, Sn+1
Cm Sn Sn
+1
Alarm and message
- PS alarm
Number Message Contents
PS0223 ILLEGAL SPINDLE SELECT An attempt was made to execute an instruction that uses
the spindle although the spindle to be controlled has not
been set correctly.
- SP alarm
Number Message Contents
SP0001 SSPA:01 MOTOR OVERHEAT An alarm (AL-01) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0002 SSPA:02 EX DEVIATION SPEED An alarm (AL-02) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0003 SSPA:03 DC-LINK FUSE IS BROKEN An alarm (AL-03) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0004 SSPA:04 POWER SUPPLY ERROR An alarm (AL-04) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0005 SSPA:XX DECODED ALARM An alarm (AL-05) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0006 SSPA:XX DECODED ALARM An alarm (AL-06) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0007 SSPA:07 OVER SPEED An alarm (AL-07) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0008 SSPA:XX DECODED ALARM An alarm (AL-08) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0009 SSPA:09 OVERHEAT MAIN CIRCUIT An alarm (AL-09) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0010 SSPA:10 LOW VOLT INPUT POWER An alarm (AL-10) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0011 SSPA:11 OVERVOLT POWER
CIRCUIT
An alarm (AL-11) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0012 SSPA:12 OVERCURRENT POWER
CIRCUIT
An alarm (AL-12) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0013 SSPA:13 CPU DATA MEMORY
FAULT
An alarm (AL-13) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0014 SSPA:XX DECODED ALARM SP0014
An alarm (AL-14) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.