B-63783EN-1/01 3.MANUAL OPERATION
- 351 -
1625 FL feedrate for each axis for acceleration/deceleration during jog feed
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
For each axis, set the FL feedrate used for acceleration/deceleration
during jog feed.
#7 #6 #5 #4 #3 #2 #1 #0
2001 MPN
[Input type] Parameter input
[Data type] Bit
# 3
# 3 # 3
# 3 MPN
MPNMPN
MPN Specifies whether the incremental feed is specified with the incremental
feed selection signals DIST0 to DIST26 or with the manual handle feed
selection signals MP1, MP2, and MP4.
0: Specified with the incremental feed selection signals DIST0 to
DIST26.
1: Specified with the manual handle feed selection signals MP1, MP2,
and PM4.
2016 Manual feedrate override clamp value
[Input type] Parameter input
[Data type] Integer
[Unit of data] 0.01%
[Valid data range] 0 - 65534
This parameter specifies the value used to clamp the manual feedrate
override when an override value larger than the manual feedrate
override clamp value is input. This parameter is valid only when the
basic machine interface (BMI) is used.
Caution
CAUTION
For incremental feeding along an axis under
diameter programming, the tool moves in units of the