1.AXIS CONTROL B-63783EN-1/01
- 64 -
5593 Straightness compensation multiplier of move axis 3
5594 Straightness compensation multiplier of move axis 4
5595 Straightness compensation multiplier of move axis 5
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 100
Specify a straightness compensation multiplier for each axis.
When the straightness compensation multiplier is set to 1, the unit
of compensation data is the same as the detection unit. When the
multiplier is set to 0, straightness compensation is not applied.
#7 #6 #5 #4 #3 #2 #1 #0
5580 SMT
[Input type] Parameter input
[Data type] Bit
# 1
# 1 # 1
# 1 SMT
SMTSMT
SMT The parameters (No. 5591 to No. 5595) for straightness compensation
multiplier:
0: Are effective only for the first move axis when two or more move axes are set
using the same axis number.
1: Are effective for the respective move axes even when two or more move axes
set using the same axis number.
Alarm and message
Number Message Contents
PW0100
ILLEGAL PARAMETER (S-
COMP.)
The parameter for setting slope compensation is incorrect. This
alarm occurs in the following cases:
• When the number of pitch error compensation points on the
axis on which slope compensation is executed exceeds 128
between the most negative side and most positive side
• When the size relationship between the slope compensation
point Nos. is incorrect
• When the slope compensation point is not located between
the most negative side and most positive side of pitch error
compensation
• When the compensation per compensation point is too small
or too great.
SV0100 S-COMP. VALUE OVERFLOW
The value set for straightness compensation has exceeded
maximum value 32,767.