B-63783EN-1/01 12.DISPLAY/SET/EDIT
- 1355 -
2212 Minimum value for the program protection range (PMIN)
2213 Maximum value for the program protection range (PMAX)
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
Programs in the range specified by these parameters can be
protected.
Specify the range of program numbers to be protected.
PMAX must be greater than PMIN.
The range can be specified when password (PSW) = 0, i.e., the key is
in a normal state or when password (PSW) = key (KEY), i.e., the key
is unlocked.
When PMIN is set to 0, it is regarded to be 9000. When PMAX is set
to 0, it is regarded to be 9999. Thus, with the default settings of
these parameters, programs 09000 to 09999 are protected.
Alarm and message
WARNING message Contents
WRITE PROTECT An attempt was made to create a program
having a program number within the
protected range. Set the unlocked state
before creating programs.
INVISIBLE PROGRAM An attempt was made to select a program
within the protected range. Set the unlocked
state before selecting programs.
Number Message Contents
PS0580 ENCODE ALARM
(PSWD&KEY)
The password does not match that on the
encrypted tape that was read.
Make the password ineffective before
attempting to read the tape.
PS0581 ENCODE ALARM
(PARAMETER)
An attempt was made to punch an encrypted
program in the EIA punch code (bit 4 of
parameter No. 0000 = 1).
Before punching the encrypted program, set
the punch code to ISO (bit 4 of parameter No.
0000 = 0).
Reference item
Series15i/150i-MB
Operator’s Manual
(Operation)
(B-63784EN)
II-8.1.4 Keys and program