5.AUTOMATIC OPERATION B-63783EN-1/01
- 480 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
2000 RWM RSD
[Input type] Parameter input
[Data type] Bit
# 0
# 0 # 0
# 0 RSD
RSDRSD
RSD The resetting (RST) signal is output:
0: Whenever the system is reset.
1: Only when the reset button is pressed on the MDI panel.
# 1 RWM The rewinding signal (RWD) is output:
0: Only while the tape is rewound in the tape reader by the reset
and rewind signal.
1: While the tape is rewound in the tape reader or the reset and
rewind signal searches memory for the beginning of a program.
#7 #6 #5 #4 #3 #2 #1 #0
2001 ENR
[Input type] Parameter input
[Data type] Bit
# 0 ENR At emergency stop:
0: The system is reset.
1: The system is not reset, but an alarm is raised. When the
system is reset, the emergency stop state is released.
#7 #6 #5 #4 #3 #2 #1 #0
2401 NCM
[Input type] Parameter input
[Data type] Bit
# 7
# 7 # 7
# 7 NCM
NCMNCM
NCM Specifies whether the following modal information is cleared by reset:
0: Cleared
1: Not cleared but saved.
G00 to G03, G17 to G19, G17.1, G93 to G95, G96 to G97, G90 to G91, F
codes, S codes, and T codes