B-63783EN-1/01 1.AXIS CONTROL
- 81 -
5422 Number of pitch error compensation point with the largest positive value for
each axis
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] From 0 through 1279 (or from 10000 through 11279) or from 0
through 3071 (or from 10000 through 13071) depending on the
number of controlled axes is less than or equal to 10 or greater than
10, respectively.
Set the number of the pitch error compensation point with the
largest positive value for each axis.
5423 Magnification of pitch error compensation for each axis
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - 100
Set the magnification of pitch error compensation for each axis.
When 1 is set as the magnification of pitch error compensation, the
unit for compensation data is the same as the detection unit.
5424 Interval of pitch error compensation points for each axis
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] See the following descriptions.
Pitch error compensation points are set at regular intervals. Set this interval for
each axis.
The minimum interval of pitch error compensation points is determined from the
following equation:
Minimum interval = maximum feedrate/7500
Unit:mm, inch, deg or mm/min, inch /min, deg/min
Example:
When the maximum feedrate is 15000 mm/min, the minimum interval of pitch error
compensation points is 2 mm.