8.MISCELLANEOUS FUNCTION B-63783EN-1/01
- 748 -
# 2
# 2 # 2
# 2 TSN
TSNTSN
TSN Specifies whether a minus (-) can be used in a T code.
0: Cannot be used
1: Can be used
# 3
# 3 # 3
# 3 BSN
BSNBSN
BSN Specifies whether a minus (-) can be used in the specification of the 2nd
auxiliary function.
0: Cannot be used
1: Can be use
2010 Delay time of the MF, SF, TF, or BF strobe signal
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 32767
Specify the time waited before the MF, SF, TF, or BF signal is sent after the M, S,
T, or B code is sent.
M, S, T, B code
MF, SF, TF, BF signal
Delay time
2011 Minimum width of the M, S, T, or B function completion (FIN) signal
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 32767
Specify the minimum signal width at which the M, S, T, or B function completion
signal (FIN) is assumed to be valid.
M, S, T, B code
MF, SF, TF, BF signal
FIN signal
Shorter than
minimum signal
width, so ignored.
Longer than
minimum signal
width, so recognized.