1.AXIS CONTROL B-63783EN-1/01
- 16 -
#7 #6 #5 #4 #3 #2 #1 #0
1005 RMB
[Input type] Parameter input
[Data type] Bitaxis
# 7
# 7 # 7
# 7 RMB
RMBRMB
RMB For each axis, specifies whether the control axis detach signal and setting
input RMV (bit 7 of parameter No. 0012) is valid.
0: Invalid.
1: Valid.
#7 #6 #5 #4 #3 #2 #1 #0
1009 MCC
[Input type] Parameter input
[Data type] Bitaxis
# 5
# 5 # 5
# 5 MCC
MCCMCC
MCC If the controlled axis is detached, the MCC signal of the servo amplifier is:
0: Turned OFF.
1: Not turned OFF.
If the controlled axis is detached when this parameter bit is 1, the servo motor is
deactivated, but the MCC signal of the servo amplifier is not turned OFF.
If the controlled axis of one motor is detached when a 2- or 3-axis amplifier is used,
this parameter bit prevents the other un-detached controlled axes from causing alarm
SV013 (IMPROPER V_READY OFF).
If, however, the connection between the CNC and the servo is released for the
detached controlled axis, alarm SV013 will be issued because of the nature of a
multiaxis amplifier.
NOTE
1 Regardless of the setting of this parameter bit (bit 5 of parameter
No. 1009), reference position return must be performed on the
removed controlled axis before the next move command.
If the next move command is executed without performing
reference position return first, P/S alarm No. 181 will be issued.
ZRN, bit 0 of parameter No. 1005, can prevent P/S alarm No. 181
from being issued.
2 Those controlled axes on which absolute-position detection is
performed (APC, bit 5 of parameter No. 1815 = 1) cannot be
removed.
3 For axes other than those of a multiaxis amplifier, set this
parameter bit, bit 5 of parameter No. 1009, to 0.