B-63783EN-1/01 12.DISPLAY/SET/EDIT
- 1317 -
1519 Active parameter set number
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 2
Stores the current active parameter set. Usually, the active parameter
set is selected by pressing the [SLCT ACTIVE] soft key on the HPCC
(SETTING) screen and, therefore, this parameter need not be directly
s
ecified.
- Setting screen
The parameters that can be set on the setting screen are listed below:
Item Parameter No.
MULTI BUFFER AUTO ENABLE MBF (No.2401#6)
FEED FORWARD (No.1883#1)
- Automatic setting
Those parameters that are set automatically are listed below:
Parameter Setting
1808#3 PI control 1
1883#1 Feed-forward enable 1
1884#4 High-speed feedrate feedback read 1
1962 Feedrate feed-forward coefficient 50 (50%)
1518 Lower limit of feed-forward coefficient for
automatic calculation
9400 (94%)
- Adjustment screen
On the adjustment screen, three parameter sets are provided for
different finish levels. In actual machining, the values selected as the
active parameters are transferred to the execution parameters and used
for machining.
FINE MEDIUM ROUGH EXEC
FINISH LEVEL 1520 1540 1560 -
ACC/DEC LEVEL 1533 1553 1573 -
ACC FOR BIPL 1534 1554 1574 1660
ACC CHANGE TIME (BELL) 1536 1556 1576 1656
MAX ACCELERATION 1535 1555 1575 1663
T-CONST AIPL ACC/DEC 1522 1542 1562 1635
CORNER FEED 1524 1544 1564 1478
FEED FORWARD COEFFICIENT 1529 1549 1569 1985
Reference item
Series15i/150i-MB
Operator’s Manual
(Operation)
(B-63784EN-1)
II-9.18 High-speed and high-
precision machining