9.SPINDLE FUNCTION B-63783EN-1/01
- 790 -
Number Message Contents
SP0045 SSPA:XX DECODED ALARM An alarm (AL-45) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0046 SSPA:46 ILLEGAL 1REV SIGN OF
SCREW CUT
An alarm (AL-46) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0047 SSPA:47 ILLEGAL SIGNAL OF
POSITION CODER
An alarm (AL-47) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0048 SSPA:XX DECODED ALARM An alarm (AL-48) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0049 SSPA:49 DEF. SPEED IS OVER
VALUE
An alarm (AL-49) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0050 SSPA:50 SYNCRONOUS VALUE IS
OVER SPEED
An alarm (AL-50) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0051 SSPA:51 LOW VOLT POWER
CIRCUIT
An alarm (AL-51) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0052 SSPA:52 ITP FAULT 1 An alarm (AL-52) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0053 SSPA:53 ITP FAULT 2 An alarm (AL-53) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0054 SSPA:54 OVERCURRENT An alarm (AL-54) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0055 SSPA:55 ILLEGAL POWER LINE An alarm (AL-55) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0056 SSPA:56 FAN FOR CONTROL
CIRCUIT IS STOP
An alarm (AL-56) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0057 SSPA:XX DECODED ALARM An alarm (AL-57) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0058 SSPA:58 MAIN CIRCUIT OVERLOAD An alarm (AL-58) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
SP0059 SSPA:59 FAN STOP An alarm (AL-59) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User's Manual.
Alarms SP001 to SP099 are detected by control units for serial spindles.
For details of alarms with these numbers, refer to the following serial
spindle manuals:
- "FANUC SERVO AMPLIFIER αi series Descriptions
(B-65282EN)"
- "FANUC SERVO MOTOR αi series Maintenance Manual
(B-65285EN)"
Number Message Contents
SP0201 MOTOR NUMBER DUPLICATE Two or more of the same motor Nos. other than "0" were
set in parameter No. 5841.
SP0202 SPINDLE SELECT ERROR A spindle No. exceeding the number of spindles were set in
parameter No. 5850.
SP0220 NO SPINDLE AMP. Either the cable connected to a serial spindle amplifier is
broken, or the serial spindle amplifier is not connected.
SP0221 ILLEGAL MOTOR NUMBER The spindle No. and the motor No. are incorrectly matched.
SP0222 CAN NOT USE ANALOG SPINDLE The machine tool does not support analog spindles.
SP0223 CAN NOT USE SERIAL SPINDLE The machine tool does not support digital spindles.
SP0224 ILLEGAL SPINDLE-POSITION
CODER GEAR RATIO
The spindle-position coder gear ratio was incorrect.
SP0225 CRC ERROR (SERIAL SPINDLE) A CRC error (communications error) occurred in
communications between the CNC and the serial spindle
amplifier.
SP0226 FRAMING ERROR (SERIAL
SPINDLE)
A framing error occurred in communications between the
CNC and the serial spindle amplifier.
SP0227 RECEIVING ERROR (SERIAL
SPINDLE)
A receive error occurred in communications between the
CNC and the serial spindle amplifier.