B-63783EN-1/01 1.AXIS CONTROL
- 145 -
# 6 PM1 Specifies whether to use the first pulse module.
0: Do not use.
1: Use.
# 7 PM2 Specifies whether to use the second pulse module.
0: Do not use.
1: Use.
1023 Servo axis number of each axis
NOTE
After this parameter has been set, the power must be off turned off
then back on for the setting to become effective.
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - Max axes
Specify the number of the servo axis that corresponds to each
control axis. Normally, set each servo and control axis to the same
numbers.
The control axis number and servo axis number of an axis with an
absolute position detector must be the same.
- If FSSB setting mode is automatic setting mode (bit 0 of
parameter No. 1090 is set to 0), setting is made automatically by
inputting data to the FSSB setting screen. In manual setting
mode (bit 0 of parameter No. 1090 is set to 1), however, data
must be entered directly.
- The servo axes are associated with servo amplifiers by setting
parameter Nos. 1080 to 1089.
- For spindle motor axes such as the spindle positioning axis and
Cs contour control axis, 0 must be set.
- For axes under tandem control and electronic gear box (EGB)
control, a pair of two axes must be set. Set these axes as follows:
Tandem axis : Set 1, 3, 5, or 7 for the master axis. For the
slave axis to be used with the master axis, set
a value greater than the value set for the
master axis by one.
EGB axis : Set 1, 3, 5, or 7 for the slave axis. For the
dummy axis to be used with the slave axis, set
a value greater than the value set for the slave
axis.