9.SPINDLE FUNCTION B-63783EN-1/01
- 958 -
9.8.1 Rigid Tapping Additional Function
- Overview
- A parameter can be used to specify whether to perform spindle
orientation when rigid tapping is started.
- A parameter can be used to specify to check whether the specified
S command exceeds the maximum spindle rotation speed for an
individual gear.
- A diagnosis screen can be used to check a synchronization error
between the tapping axis and spindle.
- Parameters
#7 #6 #5 #4 #3 #2 #1 #0
5606 ORD ORN
[Input type] Parameter input
[Data type] Bitspindle
NOTE
After this parameter has been set, the power must
be off turned off then back on for the setting to
become effective.
# 6 ORN Specifies whether to perform spindle orientation at the beginning of
rigid tapping as follows:
0: Do not perform.
1: Perform.
# 7 ORD Specifies the direction of spindle orientation at the beginning o
analog spindle rigid tapping as follows:
0: Positive direction
1: Negative direction
This parameter is valid when parameter ORN (bit 6 of parameter No.
5606) = 1.
For a serial spindle, bit 4 of parameter No. 3004 is used to specify
the direction of spindle orientation. Refer to the FANUC AC
SPINDLE MOTOR αi series Parameter Manual (B-65280EN) for
details.
NOTE
When this parameter is 0, the direction of
spindle orientation is negative if a G84.2/G84.3
block issues an I/O command (for specifying a
negative direction). When the parameter is 1,
the direction of spindle orientation is negative
also if a G84.2/G83.3 block issues an I/O
command (for specifying a positive direction).