12.DISPLAY/SET/EDIT B-63783EN-1/01
- 1354 -
Parameter
2210 Password (PSW)
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
Specify a password (PSW). When a value other than 0 is specified, the
password is assumed. When the password is specified, the display of
this parameter becomes blank, and program edition is locked. This
parameter can be specified when password (PSW) = 0, i.e., the key is in a
normal state or when password (PSW) = key (KEY), i.e., the key is
unlocked.
2211 Key (KEY)
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
Specifying the same value as the setting of PSW unlocks the key.
The specified value is not displayed.
When the power is turned on, this parameter is automatically initialized
to 0. If, therefore, the power is turned off with the key unlocked, and
then turned on again, the key is automatically unlocked.