B-63783EN-1/01 1.AXIS CONTROL
- 263 -
#7 #6 #5 #4 #3 #2 #1 #0
7712 PHD PHS
[Input type] Parameter input
[Data type] Bit
# 0
# 0 # 0
# 0 PHS
PHSPHS
PHS Specifies whether to perform acceleration/deceleration when EGB
synchronization is started or canceled if there is no R command in a
G81/G80 block.
0: Do not perform acceleration/deceleration when EGB synchronization
is started or canceled.
1: Perform acceleration/deceleration when EGB synchronization when
EGB synchronization is started or canceled, and automatically
perform phase alignment after acceleration when synchronization
starts.
# 1
# 1 # 1
# 1 PHD
PHDPHD
PHD Specifies the direction of movement for automatic phase alignment.
0: Positive (+) direction
1: Negative (-) direction
#7 #6 #5 #4 #3 #2 #1 #0
7613 ART
[Input type] Parameter input
[Data type] Bit
# 4
# 4 # 4
# 4 ART
ARTART
ART Specifies whether the retraction function based on a servo spindle alarm
is valid.
0: Not valid.
1: Valid.