B-63783EN-1/01 4.REFERENCE POSITION ESTABLISHMENT
- 463 -
1896 Capacity of the reference counter for each axis
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] 0 - 999999999
In case of using a distance coded linear scale, specifies the mark 1
interval for a distance coded linear scale.
Specifies a desired reference counter capacity. When 0 is specified
for this parameter, the standard setting (data No. 1816) is used.
Even when PLC01 of data No. 1804 is set to 1, the unit of data is
not multiplied by 10.
Turn the power on again after specifying this parameter.
5226 Mark 2 interval for a distance coded linear scale
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] 0 - 999999999
Specifies the mark 2 interval for a distance coded linear scale .