B-63783EN-1/01 1.AXIS CONTROL
- 191 -
Recovery using normal operation
This method is used if the input signal is used to switch between
synchronous operation and normal operation.
When OT513 is issued, the procedure described below can be used for
recovery.
(1) Set SYNCx (with x representing a slave axis number) to 0 for
normal operation.
(2) In parameter No. 7723 for specifying a maximum allowable
synchronous error, set a value greater than the currently set value.
Then, cancel the alarm by issuing a reset.
(3) Make a movement on the master axis or slave axis by the manual
handle, for example, to match the machine coordinates of the
master axis with those of the slave axis as closely as possible.
(4) Return the maximum allowable synchronous error set in parameter
No. 7723 to the original value.