B-63783EN-1/01 5.AUTOMATIC OPERATION
- 505 -
Signal
Block restart signal BRN <G002#6>
[Classification] Input signal
[Function] Selects block restart (block return switch).
[Operation] See the descriptions of "Manual operation when the block return switch
is on" and "Restart of automatic operation when the program return
switch is on," above.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G002 BRN
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
7605 NBC
[Input type] Parameter input
[Data type] Bit
# 7 NBC Specifies whether to check for interference when a block is restarted.
0: Check.
1: Do not check.
7651 Interference allowance when the block is restarted (d)
[Input type] Setting input
[Data type] Real
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table(A))
(When the increment system is IS-B, -999999.999 - +999999.999)
Set an allowable distance between the normal path after cutter
compensation and the block restart position.
If the distance between the normal path and restart position is equal to
or greater than d, a warning about interference is issued to protect
against overcutting.