1.AXIS CONTROL B-63783EN-1/01
- 272 -
#7 #6 #5 #4 #3 #2 #1 #0
7210 9S8 9S7 9S6 9S5 9S4 9S3 9S2 9S1
[Input type] Parameter input
[Data type] Bit
9S1 to 9S8 A skip signal to be used for G31.8 (EGB skip command) is set.
Corresponding skip signal
Parameter High-speed skip signal
( HSS(No.7200#4)=1)
DI signal
( HSS(No.7200#4)=0)
9S1 HDI0 SKIP1
9S2 HDI1 SKIP2
9S3 HDI2 SKIP3
9S4 HDI3 SKIP4
9S5 HDI4
9S6 HDI5
9S7 HDI6
9S8 HDI7
0: A corresponding skip signal is invalid.
1: A corresponding skip signal is valid.
7220 Time width from input of a skip signal until the input of the next skip signal
is enabled when the EGB skip function is used
[Input type] Parameter input
[Data type] Integer
[Unit of data] 8msec
[Valid data range] From 3 through 127. Other values are taken as 3.
Set the time width from input of a skip signal until the input of the next skip signal
is enabled (becomes acceptable) when the EGB skip function is used.
Set a value in steps of 8 msec.
Example: When 10 is set, 80 msec is assumed.
This parameter is set to prevent the system from accepting a skip signal mistakenly.
After skip signal (1), skip signal (2) is ignored because it is input within the
parameter-set time. Skip signal (3) is valid.
Parameter-set time
Skip
signal
(1)
(2)
(3)