B-63783EN-1/01 1.AXIS CONTROL
- 41 -
5424 Interval of pitch error compensation points for each axis
NOTE
After this parameter has been set, the power must be off turned off then
back on for the setting to become effective.
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] See the following descriptions.
Pitch error compensation points are set at regular intervals. Set this interval for
each axis.
The minimum interval of pitch error compensation points is determined from the
following equation:
Minimum interval = maximum feedrate/7500
Unit : mm, inch, deg or mm, min, inch, min, deg/min
Example: When the maximum feedrate is 15000 mm/min, the minimum interval
of pitch error compensation points is 2 mm.