B-63783EN-1/01 5.AUTOMATIC OPERATION
- 481 -
#7 #6 #5 #4 #3 #2 #1 #0
5605 IOR
[Input type] Parameter input
[Data type] Bitspindle
# 4 IOR Specifies whether to cancel the spindle positioning mode upon reset.
0: Do not cancel.
1: Cancel.
#7 #6 #5 #4 #3 #2 #1 #0
7000 CLV
[Input type] Parameter input
[Data type] Bit
# 6 CLV Specifies whether to clear custom macro common variables #100
through #199 (cleared when the power is turned off) upon reset.
0: Do not clear.
1: Clear to null.
#7 #6 #5 #4 #3 #2 #1 #0
7612 RSH
[Input type] Parameter input
[Data type] Bit
# 0
# 0 # 0
# 0 RSH
RSHRSH
RSH Specifies whether to cancel the synchronous mode (G81, G81.5) when th
electronic gear box function (EGB) is used.
0: Cancel upon reset.
1: Do not cancel upon reset. The synchronous mode is canceled by the
G80 or G80.5 code only.
Reference item
II-3 Properatry function
II-9.3 Spindle positionning
II-17 Custom macro
Series15i/150i-MB
Operator’s Manual
(Programming)
(B-63784EN)
II-19.9 Electric gear box