10.TOOL FUNCTION B-63783EN-1/01
- 976 -
Signal
See Section 8.1.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
2003 TSN
[Input type] Parameter input
[Data type] Bit
# 2
# 2 # 2
# 2 TSN
TSNTSN
TSN Specifies whether a minus (-) can be used in a T code.
0: Cannot be used
1: Can be used
NOTE
To enable the use of a minus (-) in a T code, the allowable
number of digits in an T code must be nine or less.
2032 Allowable number of digits in a T code
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 10
Specify the allowable number of digits in a T code.
NOTE
To set the allowable number of digits in a T code to 10, the use of
a minus "-" in a T code must be disabled.
Alarm and message
Number Message Contents
PS0003 TOO MANY DIGIT Data entered with more digits than permitted in the NC
instruction word. The number of permissible digits varies
according to the function and the word.
Reference item
Series15i/150i-MB
Operator’s Manual
(Programming)
(B-63784EN)
II-10.1 Tool selection command
Series15i/150i-
MODEL B
Connection Manual
(This manual)
8 Miscellaneous function