7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL B-63783EN-1/01
- 618 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
2400 F41
[Input type] Parameter input
[Data type] Bit
# 1
# 1 # 1
# 1 F41
F41F41
F41 If the feed per minute of F code (G94 mode) is entered in metric without
the decimal point, the unit is:
0: 1 mm/min
1: 0.1 mm/min
If it is entered with the decimal point, the unit is always mm/min.
#7 #6 #5 #4 #3 #2 #1 #0
2401 G95
[Input type] Parameter input
[Data type] Bit
# 4
# 4 # 4
# 4 G95
G95G95
G95 Mode at power on and in clear status
0: G94 mode (feed per minute)
1: G95 mode (feed per revolution)
Alarm and message
Number Message Contents
PS0187 FEED ZERO ( COMMAND ) The cutting feedrate instructed by an F code has been set to 0.
This alarm is also generated if the F code instructed for the S code
is set extremely small in a rigid tapping instruction as the tool
cannot cut at the programmed lead.
Reference item
Series15i/150i-MB
Operator’s Manual
(Programming)
(B-63784EN)
II-5.3 Cutting feed