1.AXIS CONTROL B-63783EN-1/01
- 152 -
NOTE
2 The position detector of each axis can be connected
only the pulse module connected with the same axis
control card. The position detector of each axis
cannot be connected to the pulse module connected
with other axis control cards.
Alarm and message
Number Message Contents
SV0060 FSSB:OPEN READY TIME OUT The FSSB was not in a ready to open state during
initialization.
A probable cause is an axis card malfunction.
SV0061 FSSB:ERROR MODE The FSSB entered the error mode.
Probable causes are an axis card or amplifier malfunction.
SV0062 FSSB:NUMBER OF AMP. IS
INSUFFICIENT
The number of amplifiers identified by the FSSB is less
than the number of controlled axes.
The set number of axes or the amplifier connection is
erroneous.
SV0063 FSSB:CONFIGURATION ERROR The FSSB configuration error occurred. Or, there is a
difference in the type of connected amplifier and FSSB
setting.
SV0064 FSSB:AXIS SETTING NOT
COMPLETE
Setting of axes was not completed in the automatic setting
mode.
SV0065 FSSB:OPEN TIME OUT FSSB did not open even though FSSB initialization was not
completed. Or, the connection between the CNC and
amplifier is incorrect.
SV0066 FSSB:ID DATA NOT READ Amplifier information cannot be read as FSSB is not
assigned. Or, the connection between the CNC and
amplifier is incorrect.
SV0067 FSSB:CONFIGURATION
ERROR(SOFT)
The FSSB configuration error occurred. (Detected in
software). Or, there is a difference in the type of connected
amplifier and FSSB setting.
SV0070 FSSB DISCONNECT FSSB communications was broken; the FSSB
communications cable was disconnected, or broken; the
amplifier power supply turned OFF; or, the low voltage
alarm occurred on the amplifier.
SV0071 ILLEGAL AMP. INTERFACE The axes of a 2-axis amplifier were assigned to a fast-type
interface; or, the axis setting was incorrect.
SV0072 SEND CNC DATA FAILED An FSSB communications error prevented correct data
from being sent or received by the slave.
SV0073 SEND SLAVE DATA FAILED An FSSB communications error prevented correct data
from being sent or received by the servo software.
SV0074 READ ID DATA FAILED Failed to read amplifier ID information during power ON.
SV0075 MOTOR/AMP. COMBINATION The maximum current of the motor is different from the
maximum current of the amplifier; the connection between
the axis and amplifier is incorrect; or, the parameter(No.
1788) setting is incorrect.
SV0076 ILLEGAL SETTING OF AXIS The setting is incorrect even though functions requiring
hardware for 2 axes are built into one axis.