B-63783EN-1/01 4.REFERENCE POSITION ESTABLISHMENT
- 449 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1008 SFD
[Input type] Parameter input
[Data type] Bitaxis
# 4
# 4 # 4
# 4 SFD
SFDSFD
SFD Specifies whether to enable the reference position shift function in
reference position return with the grid method.
0: Disable the function.
1: Enable the function.
1844 Grid shift amount of the reference position shift function
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] -999999999 - 999999999
Distance to the first grid point found since the deceleration dog is
turned off when the reference position shift amount (parameter No.
1850) is set to 0.
NOTE
When SFD (bit 4 of parameter No. 1008) is set to 1, the grid
amount (parameter No. 1844) is set to 0, and the reference
position shift amount (parameter No. 1850) is set to 0, a value is
automatically set. The automatically set value must not be
changed.
1850 Grid shift/reference position shift for each axis
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] 0 - 99999999
Specify the reference position shift for each axis.
NOTE
When SFD (bit 4 of parameter No. 1008) is set to 0, this
parameter indicates the "grid shift for each axis."
The grid shift must not exceed the reference counter capacity
(RC1x to RC4x (bits 0 to 3 of parameter No. 1816) or parameter
No. 1896).