B-63783EN-1/01 3.MANUAL OPERATION
- 357 -
1418 Magnification n of manual handle feed
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 2000
Set the magnification rate for when movement selection signals MP1 and MP2 for
manual handle feed are 1.
Travel amount select signal
MP4 MP2 MP1
Amount of travel
(manual handle feed)
0 0 0 Least input increment × 1
0 0 1 Least input increment × 10
0 1 0 Least input increment × m
*1
0 1 1 Least input increment × n
*2
*1 To be set in parameter No.1414.
*2 To be set in parameter No.1418.
Warning
WARNING
Rotating the handle quickly with a large
magnification such as x100 moves the tool too fast
or the tool may not stop immediately after the handle
is no longer rotated or the distance the tool moves
may not match the graduations on the manual pulse
generator. The feedrate is clamped at the rapid
traverse rate.
Caution
CAUTION
Rotate the manual pulse generator at a rate of five
rotations per second or lower.
Reference item
Series15i/150i-MB
Operator’s Manual
(Operation)
(B-63784EN-1)
II-3.4 Manual handle feed