B-63783EN-1/01 1.AXIS CONTROL
- 119 -
# 1
# 1 # 1
# 1 DGP
DGPDGP
DGP Specifies whether to set the digital servo parameters specific to the motor
at power-on.
0: Sets the digital servo parameters specific to the motor.
1: Does not set the digital servo parameters specific to the motor.
When this bit is set to 0 after the motor type is specified, the standard
settings for the motor type are automatically set at power-on. This bit is
also set to 1 at power-on.
# 6
# 6 # 6
# 6 RBK
RBKRBK
RBK Backlash compensation applied separately for cutting feed and rapid
traverse
0: Not performed
1: Performed
# 7
# 7 # 7
# 7 CNT
CNTCNT
CNT Specifies whether to specify spindle contour control for the serial
interface spindle.
0: Does not specify spindle contour control.
1: Specifies spindle contour control.
#7 #6 #5 #4 #3 #2 #1 #0
1810 NAD
[Input type] Parameter input
[Data type] Bit
# 6
# 6 # 6
# 6 NAD
NADNAD
NAD Specifies whether to perform A/D conversion of spindle or servo motor
current.
0: Performs A/D conversion.
1: Does not perform A/D conversion.
#7 #6 #5 #4 #3 #2 #1 #0
1815 APC APZ OPT
[Input type] Parameter input
[Data type] Bitaxis
# 1
# 1 # 1
# 1 OPT
OPTOPT
OPT Specifies whether to use a separate pulse coder as the position detector.
0: Does not use any separate pulse coder.
1: Uses a separate pulse coder.
NOTE