APPENDIX
B–61804E–2/05
A. SETTING DATA,
SYSTEM PARAMETER, MTF
40
Parameter
No.
Description
Initial
value
Format
1084 Integer 2 Simultaneous one–axis moving sequence (Effective when simultaneous
one axis is specified by system parameters No.0107 to 0115.)
0 : X–axis moves first in approach, while the
Z–axis moves first in escape at all times.
1 : Inner diameter, end face
Approach: Z–axis → X–axis
Escape: X–axis → Z–axis
Outer diameter
Approach: X–axis → Z–axis
Escape: Z–axis → X–axis
2 : Reverse procedure of set values in 1 (Standard setting)
3 : Z–axis moves first in approach, while X–axis moves first in escape at
all times.
Movement sequence of sequential approach and escape along one or two
axes if the Y–axis FAPT function is used (valid only when simultaneous
approach or escape along one or two axes is specified in system parameters
0400 to 0405)
0 : Approach is always started from the XY axes. Escape is always
started from the Z–axis.
1 : End face
Approach: Tool axis (Z–axis) →
Tool path (XY plane)
Escape: Tool path (XY plane) →
Tool axis (Z–axis)
Side face
Approach: Tool axis (X–axis) →
Tool path (ZY plane)
Escape: Tool path (ZY plane) →
Tool axis (X–axis)
2 : Reverse movement sequence of 1 (standard setting)
3 : Approach is always started from the Z–axis. Escape is always started
from the X, Y axes.
1085 Integer 1 Constant surface speed control
0 : Not provided
1 : Provided (G96 directly output)
2 : Provided (G97 output, then
G96 output)
G50X_ Z_ S_ ;
G97S_M03; (Dummy rotation)
G00X_ Z_ ; (Approach)
G96SX_ ; (Constant surface speed)
1090 Real number
4000. mm specification
Z–axis rapid feed rate
160. inch specification
1091 Real number
4000. mm specification
X–axis rapid feed rate (radius value)
160. inch specification
1092 Real number
–1. mm specification
Maximum value of high–precision screw lead (E code)
–
p
–1. inch specification
.
Unit: mm or inch
1093 Real number
4000. mm specification
Y–axis rapid traverse rate
160. inch specification