B–61804E–2/05
A. SETTING DATA,
SYSTEM PARAMETER, MTF
APPENDIX
55
Most significant
3 digits (detailed
classification)
RemarksFunction
Least significant
1 digit (major
classification)
5 7 0 2 The selected G code is
output.
XC plane: G17
ZX plane: G18
CZ plane: G19
5 8 0 2 G codes of MTF 1260 and
1261 are output
MTF 1260 at every minute feed, MTF 1261 at every
revolution feed
6 0 0 2 Initial point return G code is
output
The G98 is output only in the case of B, C of G code
system
6 1 0 2 G81 or G82 is output
6 2 0 2 G83 or G83.1 is output
6 3 0 2 G84 or G84.1 is output
6 4 0 2 G7.1 is output. The G code for cylindrical interpolation is output.
6 5 0 2 The G code set in MTF
1381 is output.
6 6 0 2 The G code set in MTF
1382 is output.
6 7 0 2 The G code set in MTF
1376 and 1377 is output.
7 0 0 2 The G code (G98) set to
MTF 1260 is output
G codes of MTF 1260 – 1261 are output.
CAUTION
–
7 1 0 2 The G code (G99) set to
MTF 1261 is output
–
managed. Thus, when the function code
specifying these G code output. Also, this G code
is not output when –1 is set to MTF 1260 – 1261.
8 0 0 2 The G code (G384) set to
MTF 1383 is output
8 0 0 2 The G code (G380) set to
MTF 1384 is output
(d)Output of F, S, and T codes
When the least significant 1 digit (major classification) is 3 ...
***3;
Most significant
3 digits (detailed
classification)
Least significant
1 digit (major
classification)
Function Remarks
0 0 0 3 Tool offset cancel T code
output
It depends on the setting of process parameter of
system parameter whether the T code is actually
output.
0 1 0 3 T code output Tool offset start
0 2 0 3 S code (rpm) output It is output only when the change rate from the speed
output immediately before exceeded the setting
value of MTF 1122.