B-63944EN-1/02 PROGRAMMING 6.MEMORY OPERATION BY Series 15 FORMAT
- 257 -
- Retraction after chamfering
The following table lists the feedrate, type of acceleration/deceleration
after interpolation, and time constant of retraction after chamfering.
Parameter
CFR
(No. 1611#0)
Parameter
No. 1466
Description
0 Other than
0
Uses the type of acceleration/deceleration after
interpolation for threading, time constant for
threading (parameter No. 1626), FL feedrate
(parameter No. 1627), and retraction feedrate
specified in parameter No. 1466.
0 0 Uses the type of acceleration/deceleration after
interpolation for threading, time constant for
threading (parameter No. 1626), FL feedrate
(parameter No. 1627), and rapid traverse rate
specified in parameter No. 1420.
1 Performs an in-position check before retraction
and uses the type of acceleration/deceleration
after interpolation in rapid traverse, time
constant for rapid traverse, FL feedrate, and
rapid traverse rate specified in parameter No.
1420.
By setting bit 4 (ROC) of parameter No. 1403 to 1, rapid traverse
override can be disabled for the feedrate of retraction after
chamfering.
NOTE
During retraction, the machine does not stop with
an override of 0% for the cutting feedrate
regardless of the setting of bit 4 (RF0) of parameter
No. 1401.
- Shifting the start angle
Address Q can be used to shift the threading start angle.
The start angle (Q) increment is 0.001 degrees and the valid setting
range is between 0 and 360 degrees. No decimal point can be
specified.
- Feed hold in a threading cycle
When the threading cycle retract function is not used, the machine
stops at the end point of retraction after chamfering (end point of
operation 3) by feed hold applied during threading.