6.MEMORY OPERATION BY Series 15 FORMAT PROGRAMMING B-63944EN-1/02
- 328 -
Limitation
- Axis switching
Before switching between drilling axes, cancel canned cycles for
drilling.
- Drilling
In a block that does not include X, Y, Z, R, or an additional axis,
drilling is not performed.
- P
Dwelling is performed only when address P is specified in a block.
- Q
Q must be specified in a block in which drilling is instructed.
Otherwise, data is not stored as modal data.
- Cancel
The G codes (G00 to G03) in group 01 must not be specified in the
block in which G83 is specified. This cancels G83.