1.SETTING AND DISPLAYING DATA OPERATION B-63944EN-2/02
- 264 -
7 Move the measurement probe to the second measurement point.
At this time, the CNC interlocks the machine to prevent the
probe from moving in the direction in which it was moved so as
to touch the current measurement point. For example, when the
probe touched the measurement point after being moved in the
+X direction, movement of the probe to the next measurement
point is allowed only in the -X direction. Movement in the +X,
+Y, or -Y direction is interlocked until the skip signal is set to 0.
Once the probe touches the second measurement point, follow
the same procedure as that for storing the first measurement
point.
8 Once the probe has touched the third measurement point, press
soft key [MEASUR], then [CENTER]. This calculates the
center of the hole from the coordinates of the three measured
points, then sets the X- and Y-axis workpiece origin offsets. To
cancel and restart measurement at any point, press the
RESET
key.
Pressing the
RESET
key clears the coordinates of all stored
measurement points.