A.PARAMETERS APPENDIX B-63944EN-2/02
- 308 -
NOTE
1 For the M series, when the setting of parameter
No. 6252 or 6253 is 0, the setting of parameter No.
6251 is used.
2 Set a radius value regardless of whether diameter
or radius programming is specified.
6254
ε value during automatic tool length measurement (M series) (for the XAE1
and GAE1 signals)
6255
ε value during automatic tool length measurement (M series) (for the XAE2
and GAE2 signals)
6256
ε value during automatic tool length measurement (M series) (for the XAE3
and GAE3 signals)
[Input type] Parameter input
[Data type] 2-word path
[Unit of data] mm, inch, deg (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
These parameters set the relevant ε value during automatic tool
compensation (T series) or automatic tool length measurement (M
series).
NOTE
1 For the M series, when the setting of
parameter No. 6255 or 6256 is 0, the setting
of parameter No. 6254 is used.
2 Set a radius value regardless of whether
diameter or radius programming is specified.