B-70255EN/01 6.TROUBLESHOOTING
- 95 -
904 GAS PRES. CONTROL
Displays a value specified in a pressure command for the pressure
controller that controls pressure inside the discharge tube, and sent to
the DA converter.
905 LASER TUBE PRES.
Displays the pressure inside the discharge tube.
Display range : 0 to 900
906 LASER POWER
Displays monitored laser output power values.
Unit : W
907 TRACE DATA
908 LASER SEQUENCE
No. Contents No. Contents
10 Purge completion state 23 Wait for change to discharge
start gas pressure
12 Purge being executed 26 HVON (wait for discharging)
14 75-s wait 27 Wait for base discharge
16 Exhaust pump activated 28 Power compensation in progress
17 Wait for completion of
evacuation
30 LSTR
18 Wait until specified turbo
rotation is reached
49 Evacuation at RUN OFF
20 LRDY 50 75-s wait at RUN restart
909 RF VOLTAGE 1
910 RF CURRENT 1
911 RF VOLTAGE 2
912 RF CURRENT 2
913 RF VOLTAGE 3
914 RF CURRENT 3
915 RF VOLTAGE 4
916 RF CURRENT 4
917 RF VOLTAGE 5
918 RF CURRENT 5
919 RF VOLTAGE 6
920 RF CURRENT 6