B-70255EN/01 4.INSTALLATION
- 35 -
4.3 DETAILS OF CHECKING
External gas piping leakage check (clamp test)
(1) Using an approved gas pipe, connect the gas inlet of the
oscillator to the cluster piping, or to the secondary side of the
regulator mounted on the gas cylinder.
CAUTION
As the external gas piping, use a pipe recommended
by FANUC.(See Subsection 4.4.2.)
Using a rubber hose, urethane tube, or brazed
copper pipe lowers the quality of the laser gas
guided to the oscillator, resulting in unstable
discharging.
This can lower the output level or cause a laser
power supply abnormality.
(2) Open the adjustment valve of the regulator in advance. Then,
slowly open the main valve of the gas cylinder. Next, set the
secondary pressure of the regulator to 0.175±0.025 MPa.
(3) Upon the completion of setting, close the main valve of the gas
cylinder.
(a) If the primary pressure of the regulator is abruptly reduced
to 0, gas will leak from the gas piping. Open the main valve
of the gas cylinder and locate the leaks using a liquid
leakage checker. Then, correct the leaks.
(b) If the pressure is reduced gradually, gas will leak from the
gas piping. Recheck the joints. Very occasionally, gas may
leak from the primary pressure side to the secondary
pressure side of the regulator. In such a case, the primary
pressure decreases, while the secondary pressure is
increases.
(c) A primary pressure reduction of within 10% over 8 hours is
normal.
CAUTION
If the amount of gas leakage from the gas piping is
very small, the gas composition will change more
rapidly when the pipe is longer, when the pipe
diameter is larger, or when a smaller amount of gas
is consumed. In such cases, the output will be
reduced, and discharge will tend to turn off more
easily.