10.REPLACEMENT PROCEDURES B-70255EN/01
- 152 -
1) To check whether an FET module PCB is damaged,
measure the resistance between check pins D and S
shown in the figure.
A resistance of less than 10 kW indicates that the FET
module PCB is damaged. (A normal FET module PCB
will have a resistance of about 30kW to 10MW.)
2) Mount a new FET module PCB, fix it using the screws,
then connect the cables.
(d) Checking
1) Recheck that all removed screws and disconnected
cables are securely tightened or connected.
2) Mount the top cover of the power supply.
3) Turn on the oscillator, then adjust the power supply as
described in Section 9.1.