8.OSCILLATOR CONNECTIONS B-70255EN/01
- 112 -
8.3 GAS CONTROLLER
The gas controller consists of components such as a suction unit,
exhaust unit, and pressure sensor. Fig.8.3(a) shows installation, and
Fig.8.3(b) shows piping of the gas controller respectively. The
functions of each of the components shown in the figures are outlined
below:
(1) Pressure sensor
This sensor continuously monitors the pressure in the oscillator,
from the heat exchanger on the inlet side of the turbo blower.
The sensor outputs a signal to the CNC. The sensor is of the
capacitance manometer type, which is notable for drifting little
with changes in temperature and for exhibiting very little
deterioration with time.
(2) Atmospheric pressure sensor
This sensor monitors whether the pressure in the oscillator has
reached atmospheric pressure.
(3) Filter
The filter prevents impurities from entering the oscillator.
(4) Gas pressure sensor
This sensor continuously monitors the pressure of the laser gas
supplied from an external source (such as a gas cylinder). When
the remaining amount of laser gas drops to a preset level or when
the supply pressure falls to 0.1 MPa or less, the sensor outputs
an alarm signal.
(5) Purge valve
This solenoid valve is used to fill the oscillator with laser gas so
that the gas pressure reaches the atmospheric pressure when the
unit operation is stopped. The valve is closed when the
atmospheric pressure sensor detects that the pressure in the
oscillator has reached the atmospheric pressure.
(6) External piping exhaust valve
When the oscillator is started, this valve is opened for a certain
time to allow laser gas to exhaust from the laser gas piping
between the oscillator and gas cylinder. When the oscillator is
stopped for a long time, this valve prevents gas of which
composition has changed or gas containing impurity from
entering the oscillator.
(7) Gas supply valve
This magnetic contactor opens to supply fresh laser gas to the
oscillator while the machine is operating. This valve is closed
when the unit is stopped, separating the oscillator from the
external piping.