B-70255EN/01 6.TROUBLESHOOTING
- 67 -
Alarm output condition
This alarm is issued when the enable signal in the interface becomes 0
during the time from RUN-ON to immediately before purge completion.
Enable signal in the interface
EN (bit 0 at address 00H of DI of the laser interface)
Related parameters
DGN.960#0 *ENB Enable signal in the interface
Cause of trouble Solution
1 Fuse blowing Correct the cause of the blown fuse, then
replace the fuse.
2 Anomaly of stabilized
power source unit
Check the output voltage (24V ±5%) of the
stabilized power source unit. If the allowable
voltage range is exceeded, replace the unit.
3 Anomaly of power unit of
IF PCB (A16B-2100-0141)
See Section 6.5 for details of the normal
supply voltage. If the allowable voltage range
is exceeded, replace the IF PCB.
4 Laser oscillator main
circuit breaker abnormal
Check whether the main circuit breaker is
conducting (ON).
ALM No.4070
Anomaly of chiller unit
Setting the RUN ON switch to ON causes the CNC to output a
chiller unit start signal to the machine, which will respond with a
chiller unit ready signal. The CNC monitors this signal. If the
chiller ready signal stops, the CNC issues this alarm. Check the
DGN status to confirm the signal from the chiller unit. If the
signal is abnormal, check the chiller unit.
Alarm output condition
Monitoring starts four seconds after the chiller start signal is output, and
monitoring is ended by setting RUN-OFF. If the chiller ready signal CLRDY
(G221#6) becomes 0 during monitoring, this alarm is issued.
Related parameters
G221#6 CLRDY Chiller ready signal
F221#4 CLON Chiller start request signal
ALM No.4071
Anomaly of assist gas
When starting machining, the CNC monitors for a ready signal
from the assist gas supply unit in the machine. If this signal is
not sent normally, the CNC issues this alarm.
Check the DGN status to confirm the signal from the assist gas
supply unit. If the signal is abnormal, check the assist gas supply
unit.
This alarm is issued also when in G32P
aQb, a is not 0 to 3, or b
is not 1 to 7 during program execution.
Alarm output condition
This alarm is issued when the assist gas ready signal (G221#7) becomes 0
during the assist gas output command.