B-70255EN/01 6.TROUBLESHOOTING
- 65 -
Alarm output condition
When HV is turned on, discharge starts six seconds later to reach the
maximum bias command value. After the time set in parameter No. 15222 is
passed, the voltage value of each discharge tube is compared with the value
set in parameter No. 15221. If any voltage is higher than the parameter
setting, this alarm is issued.
Related parameters
PRM.15220 Maximum bias command value
PRM.15221 Discharge start check voltage
PRM.15222 Discharge wait time
PRM.15223 Bias command
DGN.909-914 Discharge tube voltage and current
Cause of trouble Solution
1 Anomaly of parameter
setting
Make a setting using the values of
parameters listed in the parameter table
attached to the machine.
2 Anomaly of laser gas
composition
Use the laser gas with the specified
composition accuracy.
3 Discharge tube electrode
mounting bracket
loosened
Check the electrode contacts, and secure
any loose mounting brackets.
4 Leakage in vacuum
system or water leakage
Locate the leakage, and replace the
defective part.
5 The gas flow control
valve is closed
Adjust the gas flow control valve to obtain the
specified gas flow rate.
6 Matching box abnormal Replace the matching box.
7 Crack or pinhole in
discharge tube
Replace the discharge tube.
ALM No.4067
Overheating laser oscillator housing
The temperature of the input side of the electrode cooling fan is
monitored and sends alarm when it exceeds 60
°C. When the
temperature decreases, the alarm state is solved automatically.
Before that it cannot be reset. The C1000iA does not have the
sensor.
Alarm output condition
This alarm is issued when the cabinet temperature signal becomes 0 during
the time from RUN-ON to immediately before purge completion.
Cabinet temperature signal
CAT (bit 1 at address 01H of DI of the laser interface)
Related parameters
DGN.961 #1 *CAT Temperature sensor in the cabinet
Cause of trouble Solution
1 Excessive environmental
temperature
Lower the ambient temperature by ventilation
(5 to 30
°C)
2 Excessive cooling water
temperature
Set the temperature of the cooling water to
within an appropriate range (20 to 30°C).
3 Anomaly of cooling fan
motor
Replace the cooling fan motor.