9.SETTING AND ADJUSTMENT B-70255EN/01
- 134 -
(3) Remove the orange gas tube by loosening the hexagon cap nuts
securing the tube. This causes the atmospheric pressure sensor to
detect the atmospheric pressure.
(4) Clear the sensor to zero according to Section 9.5. Reinstall the
removed gas tube, and resecure the tube. After setting, check that
the LED (green) of OUT1 is on.
(5) Turn on the gas pressure control start signal (RUN), and check
that the exhaust pump starts exhaust. Then, check that the LED
(green) of the OUT1 of this sensor is turned off.
(6) This completes the setting. Set the lock mode.