6.TROUBLESHOOTING B-70255EN/01
- 82 -
Cause of trouble Solution
4 Anomaly of cable
connection
Check whether the cable is securely connected to
the turbo PCB. If not, reattach the cable.
ALM No.4106
BLOWER OIL SHORTAGE
This alarm is issued if the signal from the turbo blower oil sensor
indicates that the oil level has fallen below the setting.
Alarm output condition
This alarm is issued when the oil level signal becomes 0 during the time from
RUN-ON to immediately before purge completion.
Oil level signal
L-V (bit 2 at address 02H of DI of the laser interface)
Related parameters
DGN.962#2 *L-V Turbo blower oil
Cause of trouble Solution
1 The oil level is lower
than specified.
Replenish the turbo blower with oil until the oil
level on the oil gauge is between H and L.
Replace the oil every 1000 hours of operation.
2 Invalid alarm level
setting
Set the sensor correctly as explained in Section
9.2.
3 Sensor abnormal Replace the turbo blower.
4 Insufficient turbo blower
cooling
When the temperature of the turbo blower motor
section is high, check whether the cooling water
path is clogged. If the cooling water path is
clogged, wash the turbo blower.
ALM No.4107
MIRROR NOT INSTALLED
This alarm is issued, if the beam reflecting unit is not attached
with a mirror or mirror holder.
Because the beam reflecting unit is not mounted in the C1000iA,
this alarm is issued only when the turbo PCB is defective.
Alarm output condition
This alarm is issued when the reflecting mirror mount signal becomes 0 in
LRDY or a later step.
Reflecting mirror mount signal
M-R (bit 3 at address 02H of DI of the laser interface)
Related parameters
DGN.962#3 *M-R External reflecting mirror
Cause of trouble Solution
1 Invalid pin setting If the pin SP2 on the turbo PCB (A16B-1600-0670) is
set to "O," correct the setting to "x."
2 Faulty turbo PCB Replace the turbo PCB.