6.TROUBLESHOOTING B-70255EN/01
- 80 -
Cause of trouble Solution
2 Gas leakage from
internal piping
1)Check whether any component joints of the gas
circulating system are loose. If a loose joint is found,
tighten the joint firmly.
2)Check whether any components of the gas
circulating system have cracked. If a cracked
component is found, replace that component.
3)Check whether there is a hole in a discharge tube.
If any damage is found, replace the tube.
3 Pressure sensor
abnormal
Replace the pressure sensor.
ALM No.4100
INVETER1
If the inverter used to power the turbo blower is abnormal, this
alarm is issued.
When this alarm is issued, check that the alarm LED on the LED
indicator section of the inverter is lit. At this time, do not turn off
the power to the inverter because the alarm will be reset if the
power is turned off.
For an explanation of faults and corresponding countermeasures,
see the Subsection 6.4.10.
Alarm output condition
This alarm is issued when the inverter 1 signal becomes 0 during the time
from RUN-ON to immediately before purge completion.
Inverter 1 signal
IAL1 (bit 0 at address 02H of DI of the laser interface)
Related parameters
DGN.962#0 *IAL1 Inverter alarm 1
Cause of trouble Solution
1 Excessive intake
pressure
Check whether the values of PRM Nos. 15240,
15241, and 15242 are set according to the
attached data sheets.
2 Turbo blower rotor
locked
Replace the turbo blower. The rotor may have
locked as a result of one or more of the following
causes:
1) Foreign matter in the circulating system
2) Failed bearing
So, check for foreign matter.
3 Failed bearing in turbo
blower
Replace the turbo blower. The bearing may have
failed as a result of one or more of the following
causes:
1) Deteriorated oil
2) Foreign matter in the bearing
So, always replace the oil at the recommended
intervals.
4 Invalid inverter setting Set the inverter correctly as explained in Chapter
9.