6.TROUBLESHOOTING B-70255EN/01
- 66 -
Cause of trouble Solution
4 Anomaly of temperature
sensor
Check the continuity of the temperature
sensor. If any disconnection is found, replace
the temperature sensor.
5 Anomaly of oscillator IF
PCB(A16B-2100-0141)
Replace the faulty PCB.
6 Anomaly of connecting
cables between the PCBs.
Check the connection of each cable.
ALM No.4068
Too much incident laser beam back to the resonator.
This alarm is issued, if a workpiece reflects laser beam more
than the rating to the laser oscillator. This can happen when the
laser beam is used to drill, cut, or weld materials (such as copper,
brass, and aluminum) having a high reflectivity to the laser beam
(10.6
mm).
Alarm output condition
This alarm is issued when the actual laser output is in one of the following
conditions at the time of beam output:
(1) The actual laser output is higher than the average command power
(power x duty) by more than the value set in parameter No. 15265.
(2) The actual laser output exceeds the value set in parameter No. 15266.
The actual laser output is not monitored for five seconds after the beam is
turned on or the output is changed.
Related parameters
PRM.15215 Power input compensation coefficient
PRM.15265 Allowable output increase value
PRM.15266 Output limit
DGN.906 Actual output
Cause of trouble Solution
1 Excessive returning
beam back into the
resonator
Lower the output specified in the command, or take
an action to reduce the reflected laser beam.
2 Anomaly of parameter
for alarm detection
Check the settings of parameter Nos. 15265 and
15266 with the corresponding values in the
parameter table attached to the unit.
3 Anomaly of parameter
for output power table
Check the settings of parameter Nos.15280 to
15308 with the corresponding values in the
parameter table attached to the unit.
4 Anomaly of parameter
for input calibration
coefficient
shown in the attached
table. After replacing the rear mirror or power
sensor, it is necessary to change this parameter
setting. See Chapter 9.
ALM No.4069
Anomaly of power supply unit voltage of IF PCB
This alarm appears when there occurs the anomaly in the
stabilized power unit voltage +5,
±15, +24V of IF PCB for NC
interface.