B-70255EN/01 10.REPLACEMENT PROCEDURES
- 161 -
10.9 REPLACING THE EXHAUST UNIT
When the exhaust unit is replaced, the gas circulating system is open
to the atmosphere for a long time. Pay particular attention to the
immediate surroundings to ensure that dust and other contaminants do
not enter the gas circulating system.
Replace the exhaust unit as follows:
(1) Turn off the power to the CNC, then turn off the power to the
laser oscillator. In addition, open the main circuit breaker for the
laser oscillator.
(2) Disconnect the tubes and cables from the exhaust unit.
(3) Remove the unit securing screws, then remove the exhaust unit.
(4) Mount a new unit by reversing steps (2) and (3). Ensure that all
tubes are connected and tightened, and that the cables are
connected correctly.
(5) Perform all settings as described in Section 9.5, then check the
operation. If a laser gas flowmeter is not provided, adjust the
exhaust valve of the new exhaust control unit such that the
amount by which it opens (the angle and number of turns by
which the valve is open relative to the fully closed state) is the
same as that of the exhaust valve of the removed control unit.