Number Contents Alarm level
4061 A/D CONVERTER-1 ALARM 1
4062 A/D CONVERTER-2 ALARM 1
4063 RF POWER SUPPLY ALARM 2
4065 SHUTTER ACTION ALARM 2
4066 DISCHARGING ALARM 2
4067 LASER CABINET OH ALARM 1
4068 BEAM REFLECTION The shutter is closed and the beam is off in the LSTR state.
4069 LASER IF PCB ALARM 1
4070 CHILLER NOT READY ALARM 1
4071 ASSIST GAS NOT READY The shutter is closed and the beam is off in the LSTR state.
4072 CHILL FLOW ALARM 1
4073 LASER GAS PRES. ALARM 1
4075 CHILL TEMP. ALARM 1
4076 LASER POWER DOWN ALARM 1
4077 ABSORBER TEMP. ALARM 1
4078 LASER TUBE PRES. ALARM 1
4079 PUSH RESET KEY ALARM 2
4080 LASER TUBE EXHAUST ALARM 1
4081 GAS PRES. CONTROL ALARM 1
4082 TUBE PRES.SENSOR ALARM 1
4085 MIRROR CLEANING A warning is output. A warning can be released by a reset.
4087 SHUTTER OH ALARM 2
4088 LASER VOLTAGE DOWN ALARM 1
4089 ASSIST GAS NO SELECT
4090 LASER NOT GENERATE
The shutter is closed and the beam is off in the LSTR state.
4094 VANE PUMP ALARM 1
4099 GAS PRES.NOT REACH ALARM 1
4100 INVETER1 ALARM 1
4101 OUT OF FREQUENCY 1 ALARM 1
4105 TURBO TEMP. 1 ALARM 1
4106 BLOWER OIL SHORTAGE ALARM 1
4107 MIRROR NOT INSTALLED ALARM 2
4132 PARAMETER WAS CHANGED ALARM 2