B-70255EN/01 9.SETTING AND ADJUSTMENT
- 129 -
Code Name of function
Initial
value
Setting
value
Remarks
Multistage
speed
selection
A039 Jogging selection 00 00
00: Free run at JG stop time (disabled during operation), 01:
Gradual stop at JG stop time (disabled during operation), 02:
Direct current damping at JG stop time (disabled during
operation), 03: Free run at JG stop time (enabled during
operation), 04: Gradual stop at JG stop time (enabled during
operation), 05: Direct current damping at JG stop time
(enabled during operation)
A041 First torque boost selection 00 00
A241 Second torque boost selection 00 00
00: Manual torque boost, 01: Automatic torque boost
A042 First manual torque boost 1.0% 2.0
A242 Second manual torque boost 1.0% 1.0%
0.0 to 20.0
A043 First manual torque boost breakpoint 5.0% 10
A243
Second manual torque boost
breakpoint
5.0% 5.0%
0.0 to 50.0
A044 First control method 00 00
A244 Second control method 00 00
00: VC, 01: VP raised to the power of 1.7, 02: Free V/f setting
V/f
characteristics
A045 Output voltage gain 100 95
20 to 100
A051 Direct current damping selection 00 00
00: Disabled 01: Enabled
A052 Direct current damping frequency 0.50Hz 0.50Hz
0.00 to 60.00
A053 Direct current damping delay time 0.0s 0.0s
0.0 to 5.0
A054 Direct current damping power 0% 0%
0 to 100
A055 Direct current damping time 0.0s 0.0s
0.0 to 60.0
A056
Direct current damping edge/level
selection
01 01
00: Edge operation, 01: Level operation
A057 Start direct current damping power 0% 0%
0 to 100
A058 Start direct current damping time 0.0s 0.0s
0.0 to 60.0
Direct
current
damping
A059
Direct current damping carrier
frequency
5.0kHz 5.0kHz
0.5 to 10 derating applicable
A061 First frequency upper limiter 0.00Hz 0.00Hz
0.00, first frequency lower limiter to maximum frequency
A261 Second frequency upper limiter 0.00Hz 0.00Hz
0.00, second frequency lower limiter to second setting
maximum frequency
A062 First frequency lower limiter 0.00Hz 0.00Hz
0.00, start frequency to maximum frequency
A262 Second frequency lower limiter 0.00Hz 0.00Hz
0.00, start frequency to second setting maximum frequency
A063 Jump frequency 1 0.00Hz 0.00Hz
0.00 to 1500
A064 Jump frequency width 1 0.50Hz 0.50Hz
0.00 to 10.00
A065 Jump frequency 2 0.00Hz 0.00Hz
0.00 to 1500
A066 Jump frequency width 2 0.50Hz 0.50Hz
0.00 to 10.00
A067 Jump frequency 3 0.00Hz 0.00Hz
0.00 to 1500
A068 Jump frequency width 3 0.50Hz 0.50Hz
0.00 to 10.00
A069 Acceleration stop frequency 0.00Hz 0.00Hz
0.00 to 1500
Upper/lower
limiter/jump
A070 Acceleration stop time 0.0s 0.0s
0.00 to 60.0
A071 PID selection 00 00
00: Disabled, 01: Enabled
A072 PID P gain 1.0 1.0
0.2 to 5.0
A073 PID I gain 1.0s 1.0s
0.0 to 3600
A074 PID D gain 0.00s 0.00s
0.00 to 100.0
A075 PID scale 1.00% 1.00%
0.01 to 99.99
PID control
A076 PID feedback selection 00 00
00: Feedback 01, 01: Feedback 0
A081 AVR selection 00 00
00: On at all times, 01: Off at all times, 02: Off at deceleration
time
AVR
A082 Motor voltage selection 200/400V 200/400V
200, 215, 220, 230, 240/380, 400, 415, 440, 460, 480/575,
600
A085 Operation mode selection 00 00
00: Normal operation, 01: Power-saving operation
A086
Power-saving response/precision
adjustment
50.0s 50.0s
0.0 to 100.0
A092 First acceleration time 2 15.00s 15.00s
A292 Second acceleration time 2 15.00s 15.00s
A093 First deceleration time 2 15.00s 15.00s
A293 Second deceleration time 2 15.00s 15.00s
0.01 to 3600
A094
Stage 12 acceleration/deceleration
selection
00 00
A294
Stage 22 acceleration/deceleration
selection
00 00
00: Switching by 2 channels, 01: Switching by setting
A095 Stage 12 acceleration frequency 0.00Hz 0.00Hz
A295 Stage 22 acceleration frequency 0.00Hz 0.00Hz
A096 Stage 12 deceleration frequency 0.00Hz 0.00Hz
A296 Stage 22 deceleration frequency 0.00Hz 0.00Hz
0.00 to 1500
A097 Acceleration pattern selection 00 00
Operation
mode/
deceleration
function
A098 Deceleration pattern selection 00 00
00: Straight line, 01: S-shaped curve, 02: U-shaped curve, 03:
Reversed-U-shaped curve