E.CONTROL SEQUENCES IN LASER OSCILLATOR APPENDIX B-70255EN/01
- 252 -
VEN = ON
PCL = OFF
Wait for 5 seconds
GRDY = ON
GRDY = OFF
Control valve full close
Intra-tube pressure
<PRM.15204
Timer >
PRM.15259
ALM.4080
VEN = OFF
RBA = ON
GRDY = ON
Timer count
1
2
No
Yes
Yes
No
OFI = ON : CNC POWER OFF is invalid.
VEN = ON : Exhaust valve is opened.
PCL = ON : Alarm indication of power supply unit is valid.
GRDY = ON : Laser gas supply valve is opened.
The time required for intra-tube pressure to reach PRM15240 after
RUN ON is not definite. This is due to an evacuation system capacity
difference, exhaust pump characteristics variation, and oscillator
leakage characteristics difference. The pumping capacity further
depends on the state of oil contamination.
VEN = OFF : Exhaust valve is closed.
RBA =ON : Start of turbo blower.