11.LASER OPTICAL SYSTEM B-70255EN/01
- 192 -
11.2.2 Alignment Procedure during Installation after Transportation
(1) Record the adjustment screw readings of the output mirror
(O.C.), rear mirror (R.M.), and folding mirrors (F.M.).
(2) Collect a burn pattern, and use it as the start state for mode
adjustment. If the mode is good, end the adjustment.
Near (3m) : Hot mode and Cold mode
Far : Hot mode and Cold mode
(3) For C1000iA
1) Obtain a maximum power based on FM3.
2) Obtain a maximum power based on FM3 by using O.C. as
the reference.
3) Obtain a maximum power based on FM3 by using R.M. as
the reference.
4) Collect a burn pattern. If the mode is good, end this
procedure. If not, proceed to step 5).
5) Obtain a maximum power based on O.C. by using R.M. as
the reference. Then, repeat this procedure starting with step
2). At this time, collect a burn pattern in each step. If the
mode is finally good, end this procedure.
11.2.3 Alignment Procedure at Mirror Cleaning Time
(1) Record the adjustment screw readings of the output mirror
(O.C.), rear mirror (R.M.), and folding mirrors (F.M.).
(2) Collect a burn pattern. This is used for checking mirror dirt. If
the mode is good, end the adjustment.
Near (3m) : Hot mode and Cold mode
Far : Hot mode and Cold mode
(3) For C1000iA
1) Clean the O.C. and R.M. mirrors.
2) Obtain a maximum power based on O.C. by using R.M. as
the reference.
3) Clean the FM1 and FM2 mirrors.
4) Obtain a maximum power based on FM3.