6.TROUBLESHOOTING B-70255EN/01
- 92 -
6.5.4 Checking the IF PCB Signals
By using the IF PCB pins, check that each signal of the IF PCB is
normal. Fig. 6.5.3(a) show the pin locations.
Signal Signal function
COR Voltage to operate the laser power supply 0 to 5V
GPC Specification of pressure inside the laser tube 0 to 13V
MOUT Sampling output of monitored laser power supply currents and
voltages.
Data is output in the order: pressure, voltage (No. 1); pressure,
current (No. 1); pressure, voltage (No. 2); and so on.
LPW Monitoring of laser output power 0 to 10V
LTP Monitoring of pressure inside the laser tube 0 to 9V
1V/1.33kPa
Monitored values are clamped to 9V.
PAN1 Sampling output of monitored laser output power values and
pressure values inside the laser tube.
These two types of data are output alternately.
6.5.5 Checking the Jumper Pins
Pin Setting Description
1-2 Enables pulse command control by using external
signals (EXTP and EXTN).
SH2
2-3 Does not perform pulse command control by using
external signals. (Normal setting)
JD1 Enables communication with the CNC via a metal cable
(when JD1B is used).
LINK1
COP Enables communication with the CNC via an optical
cable (when COP1B is used).